3 and 4 Port, 0.3-1000 MHz


Цена: руб.

3 and 4 Port, 0.3-1000 MHz

3 Port Hybrids

Frequency
Range
(MHz)
Insertion
Loss
(dB)
max.
Isolation
A - B
(dB)
min.
Amplitude
Balance
(dB)
max.1
Phase
Balance
(Deg)
max.
VSWR
max.
Input
Power
(watts)
max.
P/N
0.3-20 0.8 25 0.2 2.0 1.30:1 1 JT-01-301
JT-01-411
JT-01-A
10-100 0.6 20 0.5 3.0 1.40:1 50 JTP-10-450/1N
5-200 1.2 25 0.3 4.0 1.30:1 1 JT-02-301
JT-02-411
JT-02-A
200-400 1.0 20 0.7 7.0 1.30:1 1 JT-04-301
JT-04-411
JT-04-A
5-400 1.5 20 0.3 4.0 1.50:1 1 JT-05-301
JT-05-411
JT-05-A
20-1000 1.5 17 0.5 7.0 2.00:1 1 JT-06-301
JT-06-411
JT-06-A
40-850 1.5 20 0.5 4.0 1.50:1 1 JT-07-304
Custom frequency bands and optimized specifications available.
Notes:
1.Amplitude balance is defined by input Sum or Delta to output A & B.
Available in Outline #301, 411 & A
SMA female connectors standard on outline # 411, also available with BNC, TNC, F, and N connectors.Outline 450/1N

4 Port Hybrids

Frequency
Range
(MHz)
Insertion
Loss
(dB)
max.
Isolation
A - B
(dB)
min.
Amplitude
Balance
(dB)
max.1
Phase
Balance
(Deg)
max.
VSWR
max.
Input
Power
(watts)
max.
P/N
0.3-20 0.8 25 0.2 2.0 1.30:1 1 JF-01-412
JF-01-B
5-200 1.2 25 0.3 4.0 1.30:1 1 JF-02-301
JF-02-412
JF-02-B
5-400 1.5 20 0.4 6.0 1.50:1 1 JF-03-301
JF-03-412
JF-03-B
200-400 1.0 20 0.5 7.0 1.50:1 1 JF-04-301
JF-04-412
JF-04-B
Custom frequency bands and optimized specifications available.
Notes:
1.Amplitude balance is defined by input Sum or Delta to output A & B.
Available in Outline #301, 412 & B
JF-01-* available only in #412 & B
SMA female connectors standard on outline # 412, also available with BNC, TNC, F, and N connectors.