High Power Load Terminations 582 Series


Цена: руб.

High Power Load Terminations 582 Series

 
High Power Load Terminations  582 Series
Description Features

Mi-Waves’ 582 series terminations are designed with standard waveguide flanges for use from 12.4 to 220 GHz. Each unit consists of a short length of waveguide and an integral matched terminal load.
Individual resistive dielectric loads are tapered to precise wedge configurations for maximum effective energy absorption. The gradual taper provides a low VSWR over the full waveguide bandwidth. Power requirements for the 582 series is up to 250 watts CW, please consult Mi-Wave for other power availabilities and further technical information.


Applications
The 582 series terminations are used in experimental and developmental test sets where a low VSWR wave-guide load is essential for valid and accurate measurements. These terminations will ensure precise measurement of the VSWR resulting from insertion of various waveguide components into a system.

• Low VSWR

• Compact Size

• Full Waveguide Bandwidths

• Available for High Power up
to 250 watts CW Applications

 

 

Dimensional Specifications
Model No. B
  in mm in mm
582Ku 5.00 127.0 4.00 101.6
582K 4.00 101.6 3.00 76.2
582A 4.00 101.6 3.00 76.2
582B 4.00 101.6 3.00 76.2
582U 4.00 101.6 3.00 76.2
582V 3.50 88.9 2.50 63.5
582E 3.50 88.9 2.50 63.5
582W 3.50 88.9 2.50 63.5
582F 3.00 76.2 2.00 50.8
582D 3.00 76.2 2.00 50.8
582G 3.00 76.2 2.00 50.8
 
                       
Technical Specifications
Model Number 582Ku 582K  582A  582B  582U  582V  582E  582W 582F 582D 582G
Frequency Band
(GHz)
12.4-
18.0
18.0-
26.5
26.5-
40.0
33.0-
50.0
40.0-
60.0
50.0-
75.0
60.0-
90.0
75.0-
110.0
90.0-
140.0
110.0-
170.0
140-
220
VSWR Max.
1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.15 1.15 1.15  
Average
Power (Watts)
300 250 250 200 50 50 50 25 n/a n/a n/a