Active multipliers

Millitech’s line of active multipliers offers the best performance available in the industry. These multipliers are capable of extending the range of sources from 7.5 to 20 GHz coaxial to the complete millimeter-wave spectrum from 26 to 220 GHz in waveguide outputs of WR-28, 22, 19, 15, 10, 08, 05 and 03. as well as K/2.92mm coaxial connectors.

Electrical Specifications

Model AMC-KK-CFH00 AMC-28-SFH00 AMC-22-RFH00
Output frequency (GHz) 20-40 26.5-40 33-50
Input frequency (GHz) 10-20 13.25-20 8.25-12.50
Multiplication factor 2 2 4
Input power +10dBm (nom) +10dBm (nom) +10dBm (nom)
Output power See datasheet See datasheet See datasheet
Maximum input power +13 dBm +13 dBm +13 dBm
Signal purity (max) -20 dBc -20 dBc -20 dBc
DC input (typ) 8-12 V@ 750 mA 8-12 V@ 750 mA 8-12 V@ 600 mA
Model AMC-19-RFH00 AMC-15-RFH00 AMC-12-RFH00
Output frequency (GHz) 40-60 50-75 60-90
Input frequency (GHz) 10-15 12.50-18.75 7.5-11.25
Multiplication factor 4 4 8
Input power +3dBm (nom) +10dBm (nom) +3dBm (nom)
Output power See datasheet See datasheet See datasheet
Maximum input power +13 dBm +13 dBm +13 dBm
Signal purity (max) -20 dBc -20 dBc -20 dBc
DC input (typ) 8-12 V@ 650 mA 8-12 V@ 750 mA 8-12 V@ 1.2 A
Model AMC-10-RFH00 AMC-10-RFH20 AMC-10-RFHB0
Output frequency (GHz) 75-110
(Note 6)
75-110 75-110
Input frequency (GHz) 12.50-18.33 6.25 - 9.15 12.50-18.33
Multiplication factor 6 12 6
Input power +10 dBm (nom) +10 dBm (nom) +10 dBm (nom)
Output power See datasheet See datasheet See datasheet
Maximum input power +13 dBm +13 dBm +13 dBm
Signal purity (max) -20 dBc -20 dBc -20 dBc
DC input (typ) 8-12 V@ 750 mA 8-12 V@ 850 mA 8-12 V@ 880 mA
Model AMC-08-RFH00 AMC-05-RFH00 AMC-03-RFH00
Output frequency (GHz) 90-140 140-220 220-325
Input frequency (GHz) 11.25-17.5 11.67-18.33 12.22-18.08 (6X)
Multiplication factor 8 12 18
Input power +10 dBm (nom) +10 dBm (nom) +10 dBm (nom)
Output power See datasheet See datasheet See datasheet
Maximum input power +13 dBm +13 dBm +13 dBm
Signal purity (max) -20 dBc -20 dBc -20 dBc
DC input (typ) 8-12 V@ 1A 8-12 V@ 1A 8-12 V@ 900 mA

Notes:
1) The units must be heat sunk to keep the case temperature at or below +45°C.
2) If required, heatsinks can be omitted. See “How To Order” section.
3) All testing will be at room temperature.
4) The output power is saturated.
5) The maximum DC input current is 100 mA above the typical values.
6) A narrow band version exists called the AMC-10-RNHB0. See datasheet for plot.